EFFICIENCY
Optimised design
Optimized refrigeration circuits and balanced heat exchange ensure stable dew point control with reduced power consumption across all models.
Capacity
Wide flow range
The range can cover small to large installations, providing reliable drying performance for varied compressor capacities.
Reliability
Stable dew point
Proven refrigeration systems maintain dependable moisture removal and steady outlet conditions in changing operating environments.
Optimized cooling system
PCM’s optimized refrigeration circuits maintain consistent performance under varying loads. Its efficient heat‑exchange system improves thermal transfer, stabilizes dew‑point levels, and prevents any moisture breakthrough. This combination of benefits ensures reliable air drying, as well as reduced energy waste.
Why the PCM series stands out
This series is distinguished by its ability to operate across a wide range of flow rates while maintaining a constant dew point in every installation. Proven refrigerants and high‑efficiency heat exchangers ensure reliable, long‑term performance, while the integrated coalescing filtration path enhances protection of downstream compressed air equipment.
- Stable dew point
- Wide flow capacities from 2.73 to 99.8 Nm³/min
- Reliable heat‑exchange design
- Inlet temperature of 4-49°C
- Ambient temperature of 2-43°C
- Models available with R‑134a or R‑407C refrigerants
- Configurations support varied compressor setups
Get in touch today!
With so many air treatment products available, finding the right solution can seem challenging. Our specialists are here to simplify the process and deliver options that match your exact requirements. Get in touch with us for expert advice and tailored recommendations.
Technical data
INSTALLED POWER
18
Power consumption ranges from 0.54 to 18.0 kW for efficient model selection.
FAD
99.80
PCM range: 2.73-99.80 Nm³/min for scalable drying performance.
TEMPERATURE
49
PCM units ensure stable performance with inlet temperatures from 4 to 49 °C.
| Model | Power consumption (kW) | Ambient temperature (°C) | Inlet temperature (°C) | Processing capacity (Nm3/min) | Power (V/Ph/Hz) |
|---|---|---|---|---|---|
| PCM75 | 0.54 | 2-43 | 4-49 | 2.73 | 220/1/60 |
| PCM100 | 0.64 | 2-43 | 4-49 | 3.50 | 220/1/60 |
| PCM200 | 1.3 | 2-43 | 4-49 | 6.83 | 220/1/60 |
| PCM300 | 1.8 | 2-43 | 4-49 | 10.60 | 220/1/60 |
| PCM425 | 2.55 | 2-43 | 4-49 | 14.14 | 220/1/60 |
| PCM550 | 3.53 | 2-43 | 4-49 | 18.90 | 220/1/60 |
| PCM800 | 4.5 | 2-43 | 4-49 | 28.10 | 380/3/60 |
| PCM1250 | 7.6 | 2-43 | 4-49 | 42.70 | 380/3/60 |
| PCM2000 | 10 | 2-43 | 4-49 | 66.54 | 380/3/60 |
| PCM3000 | 18 | 2-43 | 4-49 | 99.80 | 380/3/60 |
For full technical specification and more information refer to product brochure