Proven cooling
Efficient heat removal
Multi‑pass cross‑finned tubes maximize surface contact, rapidly lowering discharge temperatures for dependable drying.
Durable
Built for heavy duty
Rugged metal construction and proven thermal design ensure stable performance even in tough industrial environments.
Versatile
Wide range coverage
Models from 2.2 to 140 Nm³/min cover small workshops to large plants, ensuring consistent air cooling at any scale.
Cross finned cooling technology
At the core of the AT‑A series is KyungWon’s multi‑pass cross‑finned tube heat exchanger. This configuration increases surface area and directs air across multiple cooling stages, resulting in rapid temperature reduction and effective moisture condensation. Combined with a wide thermal operating range and stable pressure handling, this technology ensures consistent cooling performance even under fluctuating compressor loads and high‑temperature conditions.
Why the AT-A series stands out
The AT‑A series is designed to deliver dependable cooling across a wide range of compressed air installations. With broad capacity coverage, robust heat‑exchanger technology, and compatibility with various compressor configurations, it ensures stable air temperatures and enhanced protection for downstream equipment. Durability, flexibility, and proven performance make the AT‑A series a reliable solution for long‑term industrial operation.
- Supports 95°C inlet air
- Operates at up to 16 kg/cm² pressure
- Multi‑pass cross‑finned tube heat exchanger
- PT threaded connections 3/4"–6"
- Capacities from 2.2 to 140 Nm³/min
- Durable metal housings
- Compact dimensions
- Reliable moisture‑condensation cooling
- Multiple voltage configurations (220/1/50–60 or 380/3/50–60 depending on model)
- Piping flexibility and compatibility with upstream oil‑free or oil‑injected compressors
Get in touch today!
With so many air treatment products available, finding the right solution can seem challenging. Our specialists are here to simplify the process and deliver options that match your exact requirements. Get in touch with us for expert advice and tailored recommendations.
Technical data
POWER
380V
The AT‑A range supports 220V single‑phase and 380V three‑phase configurations, ensuring flexible integration on any site.
FAD
140
The series covers from 2.2 to 140 Nm³/min, offering reliable after‑cooling from small workshops to large industrial plants.
Inlet temperature
95°C
All AT‑A models handle inlet air up to 95°C, providing stable cooling performance even under high‑temperature compressor output.
| Model | Ambient temperature (°C) | Inlet temperature (°C) | Processing capacity (Nm3/min) | Power (V/Ph/Hz) | Maximum Pressure (kg/cm2) |
|---|---|---|---|---|---|
| AT-A10G2 | 20 | 95 | 2.2 | 220/1/50-60 | 16 |
| AT-A20G2 | 20 | 95 | 3.3 | 220/1/50-60 | 16 |
| AT-A30G2 | 20 | 95 | 5.2 | 220/1/50-60 | 16 |
| AT-A50G2 | 20 | 95 | 8 | 220/1/50-60 | 16 |
| AT-A75G2 | 20 | 95 | 12.7 | 220/1/50-60 | 16 |
| AT-A100G2 | 20 | 95 | 20 | 220/1/50-60 | 16 |
| AT-A150G2 | 20 | 95 | 31 | 220/1/50-60 | 16 |
| AT-A200G2 | 20 | 95 | 47 | 380/3/50-60 | 16 |
| AT-A300G2 | 20 | 95 | 62 | 380/3/50-60 | 16 |
| AT-A400G2 | 20 | 95 | 77 | 380/3/50-60 | 16 |
| AT-A500G2 | 20 | 95 | 91 | 380/3/50-60 | 16 |
| AT-A600G2 | 20 | 95 | 105 | 380/3/50-60 | 16 |
| AT-A700G2 | 20 | 95 | 120 | 380/3/50-60 | 16 |
| AT-A800G2 | 20 | 95 | 140 | 380/3/50-60 | 16 |